diagnosis
This commit is contained in:
parent
9971b7ac2e
commit
a3bc3d53cd
@ -1,3 +1,10 @@
|
||||
/*
|
||||
History:
|
||||
06.12.2023: weitere IN-requests in Autorequest übernommen
|
||||
Umschaltung mit/ohne Verkauf, während VK nur 12 wichtige, sonst alle 36
|
||||
|
||||
|
||||
*/
|
||||
#include "datIf.h"
|
||||
#include "sendWRcmd.h"
|
||||
#include "controlBus.h"
|
||||
@ -81,7 +88,8 @@ T_datif::T_datif(QObject *parent) : QObject(parent)
|
||||
dif_scanStep=0;
|
||||
selectedSlaveAddr=FIX_SLAVE_ADDR;
|
||||
cycl_running=0;
|
||||
gpi_storeDcDataValid(0); // data are not yet valid, no response from DC by now
|
||||
epi_resetDcDataValid(); // data are not yet valid, no response from DC by now
|
||||
|
||||
datif_noResponseCtr=0;
|
||||
|
||||
datif_repeatCtr=0;
|
||||
@ -137,14 +145,14 @@ char T_datif::datif_cycleSend()
|
||||
if ( !myDCIF->isPortOpen())
|
||||
{
|
||||
//qDebug() << "com port not available"; // wird ununterbrochen ausgegeben
|
||||
gpi_storeDcDataValid(0); // DC data not valid
|
||||
epi_resetDcDataValid(); // DC data not valid
|
||||
return 0;
|
||||
}
|
||||
|
||||
// supervise if DC data are valid
|
||||
datif_noResponseCtr++; // inc every 20ms
|
||||
if (datif_noResponseCtr>250) // no life sign from device controller (DC) for about 3s
|
||||
gpi_storeDcDataValid(0); // DC data has not updated for >=5s -> no longer valid!
|
||||
epi_resetDcDataValid(); // DC data has not updated for >=5s -> no longer valid!
|
||||
|
||||
// Ueberwachung ob ein oder mehrere Commands am Stueck erfolgreich waren
|
||||
if (gpi_wantToResetSupervision())
|
||||
@ -337,7 +345,7 @@ char T_datif::datif_cycleSend()
|
||||
else
|
||||
{
|
||||
dif_scanStep=0; // always start from beginning
|
||||
gpi_storeDcDataValid(0);
|
||||
epi_resetDcDataValid();
|
||||
}
|
||||
|
||||
datif_cmdWasPerformed=0; // 0: no response by now
|
||||
@ -362,8 +370,8 @@ char T_datif::sendINrequestsAutomatic(void)
|
||||
uint8_t datif_maxNrCommands=35, datif_sendNow;
|
||||
|
||||
// send quicker while transaction is ongoing:
|
||||
uint8_t datif_vendRequCommandList[15]={102,107,108,110,112,115,116,31,32,40,41,42,0,0,0};
|
||||
uint8_t datif_maxVendingCmds=12;
|
||||
uint8_t datif_vendRequCommandList[15]={102,107,108,110,112,115,116,31,32,40,41,42,23,0,0};
|
||||
uint8_t datif_maxVendingCmds=13;
|
||||
|
||||
// special commands:
|
||||
// 102: get IOs run constantly!!!
|
||||
@ -1029,7 +1037,7 @@ char T_datif::loadRecDataFromFrame()
|
||||
case 31: // Get dynamic machine conditions (doors, voltage, alarm….)
|
||||
if (RdDleng>50)
|
||||
{
|
||||
gpi_storeDcDataValid(1); // DC-Data are valid as DC responded.
|
||||
epi_setDcDataValid(); // DC-Data are valid as DC responded.
|
||||
// Could be set to every response but this (31)
|
||||
// is a very common and very important request
|
||||
gpi_storeDynMachineConditions(RdDleng, receivedData);
|
||||
|
Loading…