From a3bc3d53cd5c98eb4665aa6f56db677f6797ce86 Mon Sep 17 00:00:00 2001 From: Thomas Sax Date: Sat, 16 Dec 2023 09:39:36 +0100 Subject: [PATCH] diagnosis --- src/datIf.cpp | 22 +++++++++++++++------- 1 file changed, 15 insertions(+), 7 deletions(-) diff --git a/src/datIf.cpp b/src/datIf.cpp index 87a294a..d3af537 100644 --- a/src/datIf.cpp +++ b/src/datIf.cpp @@ -1,3 +1,10 @@ +/* +History: +06.12.2023: weitere IN-requests in Autorequest übernommen + Umschaltung mit/ohne Verkauf, während VK nur 12 wichtige, sonst alle 36 + + +*/ #include "datIf.h" #include "sendWRcmd.h" #include "controlBus.h" @@ -81,7 +88,8 @@ T_datif::T_datif(QObject *parent) : QObject(parent) dif_scanStep=0; selectedSlaveAddr=FIX_SLAVE_ADDR; cycl_running=0; - gpi_storeDcDataValid(0); // data are not yet valid, no response from DC by now + epi_resetDcDataValid(); // data are not yet valid, no response from DC by now + datif_noResponseCtr=0; datif_repeatCtr=0; @@ -137,14 +145,14 @@ char T_datif::datif_cycleSend() if ( !myDCIF->isPortOpen()) { //qDebug() << "com port not available"; // wird ununterbrochen ausgegeben - gpi_storeDcDataValid(0); // DC data not valid + epi_resetDcDataValid(); // DC data not valid return 0; } // supervise if DC data are valid datif_noResponseCtr++; // inc every 20ms if (datif_noResponseCtr>250) // no life sign from device controller (DC) for about 3s - gpi_storeDcDataValid(0); // DC data has not updated for >=5s -> no longer valid! + epi_resetDcDataValid(); // DC data has not updated for >=5s -> no longer valid! // Ueberwachung ob ein oder mehrere Commands am Stueck erfolgreich waren if (gpi_wantToResetSupervision()) @@ -337,7 +345,7 @@ char T_datif::datif_cycleSend() else { dif_scanStep=0; // always start from beginning - gpi_storeDcDataValid(0); + epi_resetDcDataValid(); } datif_cmdWasPerformed=0; // 0: no response by now @@ -362,8 +370,8 @@ char T_datif::sendINrequestsAutomatic(void) uint8_t datif_maxNrCommands=35, datif_sendNow; // send quicker while transaction is ongoing: - uint8_t datif_vendRequCommandList[15]={102,107,108,110,112,115,116,31,32,40,41,42,0,0,0}; - uint8_t datif_maxVendingCmds=12; + uint8_t datif_vendRequCommandList[15]={102,107,108,110,112,115,116,31,32,40,41,42,23,0,0}; + uint8_t datif_maxVendingCmds=13; // special commands: // 102: get IOs run constantly!!! @@ -1029,7 +1037,7 @@ char T_datif::loadRecDataFromFrame() case 31: // Get dynamic machine conditions (doors, voltage, alarm….) if (RdDleng>50) { - gpi_storeDcDataValid(1); // DC-Data are valid as DC responded. + epi_setDcDataValid(); // DC-Data are valid as DC responded. // Could be set to every response but this (31) // is a very common and very important request gpi_storeDynMachineConditions(RdDleng, receivedData);